Plaster Boards

ARTIPAN® Fireproof Plasterboard is composed of high purity reinforced of noncombustible gypsum core by the additives and glass fiber with the special surface cardboards at our high technology production line

ADVANTAGES

*Through its special surface cardboards, it allows having a smooth surface and provide excellent base for ceramic and tile coating or prior to a variety of decorative applications by use of ATIŞKAN® Cement Based adhesive mortar.

*It minimizes problems arising from handling, application and use due to its high resistance,

*As a ‘breathable’ material, it balances the ambient humidity and helps formation of healthy environments.

*Besides being easy to prepare, apply and disassemble, it helps saving time and labor, permitting to pass the installation and insulation materials through the application cavities.

*Compared to the conventional wall applications, it considerably decreases the building wall loads and reduces the beam, column and slub sizes, thus minimizing the construction costs.

*It protects the structural members of the building due to its high fire resistance and provides emergency response corridors during fire

APPLICATION SURFACES

Partition walls, cladding walls and suspended ceilings.

APPLICATION CONDITIONS

*It should not be applied under conditions at 4oC and below.

*The application should be made by auxiliary materials which should be in accordance with the standart.

SURFACE PREPARATION

The application surface should be made free of any dust, dirt, grease, paint and weak decoration products. If required, the application surface is fixed with Esfix Joint Filling Mortar.

WARNINGS AND PRECAUTIONS

*In case of partition walls, maximum axis opening of 60cm. should be allowed between the profiles for dry environment. For wet area, high wall and load bearing, the axis openings should be reduced down to 30cm. Depending on the conditions, DC profile width should be increased.

*For ceiling applications, the openings of the axis connected to the board direction, the axis openings should be 50cm. vertically and 40cm.

APPLICATION RESTRICTIONS

*When high level sound and thermal insulation is required, it should be used together with proper insulation material. For ceiling application, you should use extra fastening components.

*Any damaged board and auxiliary materials should be renewed and application should not be made by any defective materials.

STORAGE CONDITIONS

In order that the plasterboards are not damaged, store them on a flat and clean floor also It will not contact directly with the ground and should be stored in areas that offer protection against adverse conditions (condensation, humidity, etc.)

TECHNICAL CHARACTERISTICS

Length

2000 - 3600 mm

Width

1200 mm

Thickness

9.5 mm

12.5 mm

15 mm

Average Weight

≤ 7.5 kg/m²

≤ 10 kg/m²

≤ 12 kg/m²

Flexural Strength (Perpendicular to Paper Fibers)

≥ 400 N

≥ 550 N

≥ 650 N

Flexural Strength (Parallel to Paper fibers)

≥ 160 N

≥ 210 N

≥ 250 N

Type of edge

IK (Tapered edge) – KK (Square Edge)

Thermal Conductivity Value (λ)

0.23 W/mK

Fire Class

A2 – s1, d0 (as per TS EN 520 Annex B)

Core Strength (when exposed to fire)

≥ 15 min

Coefficient of resistance to Water Vapor Transmission

10

Standard

TS EN 520

PACKAGING

Thickness

9.5 mm

12.5 mm

15 mm

Pallet/Board

60 pcs./Pallet

50 pcs./Pallet

40 pcs./Pallet